GoWebScan API
|
| kStatus GoWebScanSettings_SetCalYAdjustment | ( | GoWebScanSettings | settings, |
| k32s | value | ||
| ) |
Sets the offset applied to the Y-coordinates of all data (profile, vision, tracheid) in Web or Detection mode (mils).
This setting is used for Y-alignment between multiple servers, and should be written by the user application at the end of system calibration. The Y-reference for a single server is calculated during system calibration and available through GoWebScanCal_SystemYRef. The user application should calculate the overall Y bias, which is done by averaging the Y-references from all servers, and set the Y-adjustment for each server as the Y bias minus the server's own Y-reference.
| settings | GoWebScanSettings object. |
| value | Y adjustment offset (mils). |