EtherNet/IP Protocol

EtherNet/IP is an industrial protocol that allows bidirectional data transfer with PLCs that support the protocol. It encapsulates the object-oriented Common Industrial Protocol (CIP). EtherNet/IP communication enables the client to:

Implicit messaging is always enabled.

This section describes the EtherNet/IP message and data formats. The commands described in the sections below are those specific to the Gocator protocol and not the complete EtherNet/IP reference command set.

GoPxL supports EtherNet/IP communication to provide system, sensor group, and scan output data to a PLC. Sensors also accept incoming commands. After you enable EtherNet/IP in the GoPxL web interface, the sensor starts listening on the standard EtherNet/IP port 44818 for one or more EtherNet/IP clients. GoPxL operates as an EtherNet/IP server, and a PLC that connects to it acts as the EtherNet/IP client. All communication is initiated by the PLC, with GoPxL responding to the EtherNet/IP requests.

While the EtherNet/IP protocol includes several types of requests, the two basic operations are reading and writing EtherNet/IP objects. Commands are invoked by the PLC sending set requests. Data is requested by the PLC by sending get requests for EtherNet/IP objects.

EtherNet/IP supports both explicit messaging and implicit messaging. Data can be read as Big-Endian format or Little-Endian format based on the configuration selected in web interface.

Connections Map

The EtherNet/IP protocol supports the following objects. Except for mandatory objects, all objects are mapped to a register assembly.

Mandatory Objects

Mandatory objects are present in the EtherNet/IP service irrespective of the configured measurement objects.

Assembly Objects

All assembly objects are modeled with class 4 and attribute 3. Only the instance ID changes between assembly objects.

A register assembly contains register blocks. This is a one-to-one mapping, which means each EtherNet/IP assembly object will have a corresponding control framework register assembly. These objects are added to GoPxL irrespective of the selection of register assembly, but the data is added to this EtherNet/IP object based on the selection of register assembly.

Assembly Objects

Object name

Register assembly

Supported Register Block Type

Service

Instance ID
Command input object Control Input register assembly "ControlInput" SetAttributeSingle (0x10) 0x70
Command output object Control Output register assembly "ControlOutput"  GetAttributeSingle(0x0E) 0x71
Sensor Group State object Sensor Group State register assembly "Scanner" GetAttributeSingle(0x0E) 0x72
System State object System State register assembly "System" GetAttributeSingle(0x0E) 0x73
Sample State object Sample State register assembly

"Stamp"

"Measurement"

GetAttributeSingle(0x0E) 0x74
Implicit Messaging output object Sample State register assembly

"Stamp"

"Measurement"

GetAttributeSingle(0x0E) 0x65
Implicit Messaging input object Implicit Control Input register assembly "ControlInput" SetAttributeSingle (0x10) 0x64

fThe EtherNet/IP protocol supports various blocks types. Each block type can be either an input block or an output block. Input blocks contain write-only objects and are used by the EtherNet/IP client to send commands such as starting or stopping a scan. Output blocks contain read-only objects and are used to store various types information, such as control, system, and sensor group state data, as well as scan output data.

Supported Block Types

The block types supported by the EtherNet/IP protocol are listed in the table below. The size field indicates the number of registers that each block type requires.

Supported Block Types

Block Type

Read or Write only?

Size (number of EtherNet/IP registers)

Description

"ControlInput" WO 67

Command message set by the Ethernet IP client.

"ControlOutput" RO 3 Result data corresponding to a command that was written to the Control Input block.
"System" RO 76

Information about the LMI device.

"Scanner" RO 18 Information about a specific scanner.
"Stamp" RO 33

Stamp message information.

"Measurement" RO 5 Measurement data of a scan output measurement data message.

Control Input

The input of the Control Input block contains the fields described below:

Control Input Fields

Field

Type

Address offset

Description

Command Sequence Number 16u 0

The command sequence number is set by the external client to uniquely identify a command request. This number is sent back in the Control Output.

This is an optional field but is recommended that Ethernet IP clients use this to help the clients correlate the Command Status in the Control Output with a specific command request in Control Input.

Command Identifier 8u 2

Identifies the requested action from the external client. 

Supported actions:

0 = No Command

1 = Start Scanning

2 = Stop Scanning

3 = Align Sensor Group

4 = Clear Alignment

5 = Load Job File

6 = Software Trigger

 

Command Arguments

Array[8u]

3

Arguments for commands that require arguments.

For the Load Job File command, the command arguments will contain the null terminated job file name. The job file name must not include the job file extension. The job extension is automatically appended by the Ethernet IP server.

This field takes up a maximum of 64 registers. Each byte contains a single character.

Control Output

The output of the Control Output block contains the fields described below:

Control Outpu Fields

Field

Type

Address offset

Description

Command Sequence Number 16u 0 The command sequence number received from the client in the Control Input.
Command Status 8u 2

Status of the command, referenced by the Command Sequence Number.

0 = No Command Received

1 = In Progress

2 = Success

3 = Fail

System State

The output of the System State block contains the fields described below:

System State Fields

Field

Type

Address offset

Description

System Uptime 64u 0 Amount of time the application has been running, in seconds.
System State 8u 8

Whether system is running or not.

0 = System is stopped

1 = System is running

Current Job File Name Length 8u 9 Number of characters in the current job file name.
Current Job File Name Array[8u] 10

Name of the job file currently loaded into the system, including extension.

Maximum length of job file name is 64 characters. Each register contains a single character.

Job file name is NOT null terminated.

Buffer Count 8u 74

The current amount of buffered scan output data when buffering is enabled.

Buffer Overflow 8u 75

A value of 0 indicates that no overflow has occurred.

A value of 1 indicates that overflow occurred and data is being lost.

Sensor Group State

The output of the Scanner (Sensor Group) Block contains the fields described below:

Sensor Group State Fields

Field

Type

Address offset

Description

Current Encoder Position 64s 0 The current encoder position.
Current Sync Time 64u 8

Current time of the clock used to stamp all scan output messages, in microseconds.

Alignment State 8u 16

Indicator of whether all devices under the sensor group are aligned (that is, devices in the sensor group all have a non-identity transform matrix).

0 = Not Aligned

1 = Aligned

2 = Aligning

Laser Enabled 8u 17

Whether one or more devices under the sensor group has its laser enabled to be able to turn on. 

0 = All devices' lasers are disabled and cannot turn on

1 = One or more devices' lasers can be turned on

Stamp

The output of the Stamp Block contains the fields described below:

Stamp Fields

Field

Type

Address offset

Description

Z Position 64s 0 Encoder position at time of last index pulse of last frame. 
Encoder Position 64s 8 Encoder position of last frame when the image data was scanned/taken. 
Time 64u 16 Time stamp, in microseconds, of last frame.
Frame Index 64u 24

The frame number of the last frame.

Digital Input States 8u 32

Digital input states of last frame.

Bit 0: State of digital input 1 on master or sensor

Bit 1: State of digital input 2 on master or sensor

Measurement

The output of the Measurement Block contains the fields described below:

Measurement Fields

Field

Type

Address offset

Description

Value 32s 0

Measurement value. This value is the actual measurement value multiplied by 1000.

If the measurement value is invalid, the 32-bit value is set to 0x80000000.

Decision 8u 4

Measurement decision.

Bit 0: 

0 = Fail

1 = Pass

 

Bit 1:

0 = Decision value is valid

1 = Decision value is invalid