Gocator 3210 Sensor
The Gocator 3210 is defined below:
MODEL |
3210 |
---|---|
Scan Rate (Hz) |
6 |
Imagers (megapixels) |
2 |
Clearance Distance (CD) (mm) |
164.0 |
Measurement Range (MR) (mm) |
110.0 |
Field of View (mm) |
71.0 x 98.0 - 100.0 x 154.0 |
Repeatability Z (µm) |
4.7 |
Resolution XY (mm) |
0.060 - 0.090 |
VDI/VDE Accuracy (mm)* |
0.035 |
Dimensions (mm) |
49 x 146 x 190 |
Weight (kg) |
1.7 |
Light Source | Blue LED (465 nm) |
Interface | Gigabit Ethernet |
Inputs | Differential Encoder, Trigger |
Outputs |
2x Digital output, RS-485 Serial (115 kBaud) Analog Output (4 – 20 mA) |
Input Voltage (Power) | +24 to +48 VDC (50 Watts); Ripple +/- 10% |
Housing | Gasketed aluminum enclosure, IP67 |
Operating Temp. | 0 to 45° C |
Storage Temp. | -30 to 70° C |
Vibration Resistance | 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours per direction |
Shock Resistance | 15 g, half sine wave, 11 ms, positive and negative for X, Y and Z directions |
* Based on 2634, Part 2.
Linearity Z values and Resolution Z are typical values.
Field of View and Resolution XY are specified as [X] x [Y], near to far.
Differential encoder requires the use of Master 400/800/810/1200/2400/2410.
The following diagram illustrates some of the terms used in the table above.
Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the following pages.