Gocator 2400 Series

The Gocator 2400 series consists of the following models:

MODEL 2410 2420 2430 2440 2450 2490

Scan Rate (Hz)

200 Hz, up to 5 kHz 200 Hz, up to 5 kHz 320 - 5000 310 - 5000 270 - 5000

370 Hz (full view) or

800 Hz (configured for 1m x 2m field of view) to 5000 Hz

Data Points / Profile

1710 1940 1500 1500 1800 1920

Linearity Z
(+/- % of MR)

0.015 0.006 0.01 0.01 0.01 0.04

Resolution X (mm)

(Profile Data Interval)

0.0058 - 0.0062 0.014‬ - 0.0165 0.037 - 0.057 0.09 - 0.13 0.100 - 0.255 0.25 - 1.1
Repeatability Z (µm) 0.2 0.4 0.8 1.2 2.0 12

Clearance
Distance (CD) (mm)

19 60 75 183 270 350

Measurement
Range (MR) (mm)

6 25 80 210 550 1525
Field of View (FOV) (mm) 10 - 10 27 - 32 47 - 85 96 - 194 145 - 425 390 - 2000
Laser Classes

2M, 3R (blue, 405 nm)

2, 3R, 3B (red, 660 nm;
blue, 405 nm)

2, 3R, 3B (blue, 405 nm)

2, 3R (red, 660 nm)

Dimensions (mm) 44x90x145 44x90x145 44x90x155 44x90x190 44x90x240 49x85x272
Weight (kg) 0.88 0.88 1.0 1.2 1.2 1.5

The following diagram illustrates some of the terms used in the table above.

Optical models, laser classes, and packages can be customized. Contact LMI for more details.

Specifications stated are based on standard laser classes. Linearity Z, Resolution Z, and Repeatability Z may vary for other laser classes.

All specification measurements are performed on LMI’s standard calibration target (a diffuse, painted white surface).

Linearity Z is the worst case difference in average height measured, compared to the actual position over the measurement range.

Resolution Z is the maximum variability of height measurements across multiple frames, with 95% confidence.

Resolution X is the distance between data points along the laser line.

Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95% confidence variation of the average height over 4096 frames. Height values are averaged over the full FOV.

See Resolution and Linearity for more information.

ALL 2400 SERIES MODELS

 

Interface Gigabit Ethernet
Inputs Differential Encoder, Laser Safety Enable, Trigger
Outputs 2x Digital output, RS-485 Serial (115 kBaud), 1x Analog Output (4 - 20 mA)
Housing Gasketed aluminum enclosure, IP67
Input Voltage (Power)

+24 to +48 VDC (9 W; 13 Watts for Gocator 2490); Ripple +/- 10%

Operating Temp. 0 to 50° C
Storage Temp. -30 to 70° C

Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the following pages.