Gocator 2500 Series
The Gocator 2500 series consists of the following models:
MODEL | 2510 | 2512 | 2513 | 2520 | 2522 | 2530 |
2540 |
2550 |
---|---|---|---|---|---|---|---|---|
Data Points / Profile |
1920 | 1920 | 600 | 1920 | 1920 | 1920 |
1920 |
1920 |
Scan Rate (Hz) * | 2400 - 20000 | 2400 - 20000 | 14500 - 20000 | 1600 - 20000 | 1600 - 20000 | 2000 - 20000 |
1700 - 20000 |
1800 - 20000 |
Resolution X (µm) (Profile Data Interval) |
8.0 | 8.0 | 16.0 | 13.0 - 17.0 | 13.0 - 17.0 | 28.0 - 54.0 |
64-160 |
80-270 |
Linearity Z (+/- % of MR) | 0.015 | 0.015 | 0.019 | 0.006 | 0.006 | 0.01 |
0.05 |
0.06 |
Repeatability Z (µm) ** | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.5 |
1.2 |
2.0 |
Clearance |
17.0 | 17.0 | 66.5 | 47.5 | 17.75 | 40 |
152 |
216 |
Measurement |
6 | 6 | 6 | 25 | 25 | 80 |
295 |
595 |
Field of View (FOV) (mm) | 13.0 - 14.5 (diffuse) |
13.0 - 14.5 (diffuse & specular) |
10.0 | 25 - 32.5 (diffuse) |
25.0 - 32.5 (diffuse) 25.0 (specular) |
48 - 100 (diffuse) |
120-292 |
154-518 |
Laser Classes |
2 (blue, 405 nm) |
2 (blue, 405 nm) |
3B (blue, 405 nm) |
2 (blue, 405 nm) |
2 (blue, 405 nm) |
2, (blue, 405 nm) |
2, 3R, 3B (blue, 405 nm) |
2, 3R, 3B 2 (blue, 405 nm) |
Dimensions (mm) | 46x80x110 | 46x80x110 | 46x80x110 | 46x80x110 | 46x110x110 | 46x80x110 |
55x105x195 |
55x105x195 |
Weight (kg) | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 1.48 | 1.48 |
* Speed Ranges are from default configuration (full field-of-view and full measurement range) to high speed configuration (reduced field-of-view and measurement range, uniform spacing disabled, optimized data spacing and output, acceleration enabled).
** These results are achieved with LMI standard target and optimized sensor configuration.
The following diagram illustrates some of the terms used in the table above.
|
Unlike other Gocator line profile sensors, the clearance distance for Gocator 2500 sensors is measured from the lowest point of the sensor's housing, not the laser window. |
Specifications stated are based on standard laser classes. Linearity Z and Repeatability Z may vary for other laser classes.
All specification measurements are performed on LMI’s standard calibration target (a diffuse, painted white surface).
Linearity Z is the worst case difference in average height measured, compared to the actual position over the measurement range.
Resolution X is the distance between data points along the laser line.
Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95% confidence variation of the average height over 4096 frames. Height values are averaged over the full FOV.
See Resolution and Linearity for more information.
ALL 2500 SERIES MODELS |
|
---|---|
Interface | Gigabit Ethernet |
Inputs | Differential Encoder, Laser Safety Enable, Trigger |
Outputs | 2x Digital output, RS-485 Serial (115 kBaud) |
Factory Communication | PROFINET, Modbus, EtherNet/IP, ASCII, Gocator |
Housing | Gasketed aluminum enclosure, IP67 |
Input Voltage (Power) | +24 to +48 VDC (15 W); Ripple +/- 10% |
Operating Temp. | 0 to 40 °C; for Gocator 2540 and 2550, 0 to 45 °C |
Storage Temp. | -30 to 70 °C |
Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the following pages.