Gocator 2500 Series

The Gocator 2500 series consists of the following models:

MODEL 2510 2512 2513 2520 2522 2530

2540

2550

Data Points / Profile

1920 1920 600 1920 1920 1920

1920

1920

Scan Rate (Hz) * 2400 - 20000 2400 - 20000 14500 - 20000 1600 - 20000 1600 - 20000 2000 - 20000

1700 - 20000

1800 - 20000

Resolution X (µm)

(Profile Data Interval)

8.0 8.0 16.0 13.0 - 17.0 13.0 - 17.0 28.0 - 54.0

64-160

80-270

Linearity Z (+/- % of MR) 0.015 0.015 0.019 0.006 0.006 0.01

0.05

0.06

Repeatability Z (µm) ** 0.2 0.2 0.4 0.4 0.4 0.5

1.2

2.0

Clearance
Distance (CD) (mm)

17.0 17.0 66.5 47.5 17.75 40

152

216

Measurement
Range (MR) (mm)

6 6 6 25 25 80

295

595

Field of View (FOV) (mm) 13.0 - 14.5
(diffuse)
13.0 - 14.5
(diffuse & specular)
10.0 25 - 32.5
(diffuse)

25.0 - 32.5 (diffuse)

25.0 (specular)

48 - 100
(diffuse)

120-292

154-518

Laser Classes

2 (blue, 405 nm)

2 (blue, 405 nm)

3B (blue, 405 nm)

2 (blue, 405 nm)

2 (blue, 405 nm)

2, (blue, 405 nm)

2, 3R, 3B

(blue, 405 nm)

2, 3R, 3B

2 (blue, 405 nm)

Dimensions (mm) 46x80x110 46x80x110 46x80x110 46x80x110 46x110x110 46x80x110

55x105x195

55x105x195

Weight (kg) 0.65 0.65 0.65 0.65 0.65 0.65 1.48 1.48

* Speed Ranges are from default configuration (full field-of-view and full measurement range) to high speed configuration (reduced field-of-view and measurement range, uniform spacing disabled, optimized data spacing and output, acceleration enabled).

** These results are achieved with LMI standard target and optimized sensor configuration.

The following diagram illustrates some of the terms used in the table above.

Unlike other Gocator line profile sensors, the clearance distance for Gocator 2500 sensors is measured from the lowest point of the sensor's housing, not the laser window.

Specifications stated are based on standard laser classes. Linearity Z and Repeatability Z may vary for other laser classes.

All specification measurements are performed on LMI’s standard calibration target (a diffuse, painted white surface).

Linearity Z is the worst case difference in average height measured, compared to the actual position over the measurement range.

Resolution X is the distance between data points along the laser line.

Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95% confidence variation of the average height over 4096 frames. Height values are averaged over the full FOV.

See Resolution and Linearity for more information.

ALL 2500 SERIES MODELS

 

Interface Gigabit Ethernet
Inputs Differential Encoder, Laser Safety Enable, Trigger
Outputs 2x Digital output, RS-485 Serial (115 kBaud)
Factory Communication PROFINET, Modbus, EtherNet/IP, ASCII, Gocator
Housing Gasketed aluminum enclosure, IP67
Input Voltage (Power) +24 to +48 VDC (15 W); Ripple +/- 10%
Operating Temp. 0 to 40 °C; for Gocator 2540 and 2550, 0 to 45 °C
Storage Temp. -30 to 70 °C

Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the following pages.