Laser Safety Input
The Safety_in+ signal should be connected to a voltage source in the range listed below. The Safety_in- signal should be connected to the ground/common of the source supplying the Safety_in+.
|
You should not use the Laser Safety input to start and stop the laser. Instead, use the digital input for triggering the laser; for more information, see Digital Input. |
Function | Pins | Min | Max |
---|---|---|---|
Safety_in+ |
J |
24 V |
48 V |
Safety_in- |
G |
0 V |
0 V |
|
Confirm the wiring of Safety_in- before starting the sensor. Wiring DC_24-48V into Safety_in- may damage the sensor. |